Seamless Knit Nylon Glove with Polyurethane Advanced Barrier Protection Coating on Full Hand – Touchscreen
GP33VRX180
3111
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
The ANSI/ISEA 105-2016 blunt force puncture testing uses a probe to simulate a tear or burst hazard. The test measures the amount of force needed for a blunt probe to pierce through PPE material. Results are given in Newtons, which is converted into a 1-5 scale and spans from 10 newtons (Level 1) to 150+ newtons (Level 5) of puncture resistance.
The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.
Reusing or laundering products not only reduces cost, but also reduces the amount of waste that is put into our landfills in turn reducing the environmental impact.
ESD is an acronym for electrostatic discharge. This discharge is the rapid transfer of static between two different objects. Although ESD doesn’t typically cause harm to the human body - you might only experience it as a small, surprising shock - it can cause extensive damage to electrical equipment and sensitive instruments. This damage may either be permanent, causing the device to malfunction (known as a catastrophic failure), or it may occur on a smaller scale that would be difficult to detect before the device is sent out for service (known as latent defect).
In accordance with ASTM D6978-05, Personal Protective Equipment can be tested to ensure an effective barrier against Fentanyl. The ASTM D6978-05 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drug tests a breakthrough time of typically 240 minutes to determine if the PPE provides an effective barrier.
A common misconception is that touchscreens work based on heat from fingers. It's not heat that generates touchscreen functionality, instead, most screens work either on finger pressure applied or electrical field disruption. Basically, this means there are two main types of touchscreen technologies, Resistive and Capacitive.
Click here for more information about Resistive and Capacitive Touchscreens
Available Colors:
Nylon: Seamless nylon liner offers increased comfort, finger dexterity and breathability.
Polyurethane: Polyurethane (PU) is a tough, proven material that offers good tactile sensitivity by way of its thin material deposit. It conforms intimately over multiple glove liners to provide flexibility, dexterity and tactile sensitivity. PU coated gloves are among the most commonly used because they are versatile and provide excellent value. Newer, water-based PU coatings offer improved flexibility and less environmental lifecycle impact.
Foam: Available in Nitrile, NeoFoam® and PVC, foam coating cell structure is designed to channel fluids away from the surface of the object helping improve grip in slightly oily/wet conditions. Secure grip in dry conditions. Oily/wet grip varies with density of cell structure.
Ideal for handling and assembly of small to medium sharp parts and materials, manufacturing, inspection, shipping and packaging and mechanical equipment maintenance and repair.
Abrasion: 3 Cut (Coupe Test): 1 Tear: 1 Puncture: 1 Cut (TDM-100 Test): X Impact Protection: X
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
Test Method: ASTM F1342
The ANSI/ISEA 105-2016 blunt force puncture testing uses a probe to simulate a tear or burst hazard. The test measures the amount of force needed for a blunt probe to pierce through PPE material. Results are given in Newtons, which is converted into a 1-5 scale and spans from 10 newtons (Level 1) to 150+ newtons (Level 5) of puncture resistance.
The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.
Reusing or laundering products not only reduces cost, but also reduces the amount of waste that is put into our landfills in turn reducing the environmental impact.
Test Method: ASTM D6978-05
In accordance with ASTM D6978-05, Personal Protective Equipment can be tested to ensure an effective barrier against Fentanyl. The ASTM D6978-05 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drug tests a breakthrough time of typically 240 minutes to determine if the PPE provides an effective barrier.
The G-Tek® brand is applied to seamless knit coated gloves used for various cut protection and general purpose applications for various industrial, construction, and MRO applications. As a comprehensive line of hand protection, G-Tek® encompasses several technology platforms to meet the various needs of the market. Each cut resistant glove is tested to both ANSI and EN standards, and test scores are readily available on each product’s webpage.
View ProductsPrivacy Policy | Contact Us | Full Site
© 2012-2025 Protective Industrial Products, Inc. All rights reserved.
CALL US TODAY: (514) 409-2859
CUSTOMER SERVICE DIRECT: (877) 446-3278