EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
JKL
EN 374 Results: JKL Type: B J: Heptane K: Sodium Hydroxide 40% L: Sulfuric Acid 96%
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
ANSI/ISEA has released a new edition of the ANSI/ISEA 105 standard (2024 ed). The changes include a new standardized glove label for easier identification of key protection levels for both distributors and end-users. The new pentagon marking was created to simplify and standardize the identification of protective glove performance levels, including abrasion, cut, and puncture resistance. By consolidating this information into a single, easily recognizable label, it improves usability for workers and reduces the risk of selecting inadequate protection. Learn more.
EN 388 2016 Results: 4321BX Abrasion: 4 Cut (Coupe Test): 3 Tear: 2 Puncture: 1 Cut (TDM-100 Test): B Impact Protection: X
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
EN 388 2016 Results: 3X01X Abrasion: 3 Cut (Coupe Test): X Tear: 0 Puncture: 1 Cut (TDM-100 Test): Impact Protection: X
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
ABK
EN 374 Results: ABK Type: B A: Methanol B: Acetone K: Sodium Hydroxide 40%
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
VIRUS
Protective Gloves Against Micro-organisms
The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.
Electrostatic Properties
EN 16350 European standard defines the test conditions and requirements for electrostatic properties of protective gloves used in ATEX area (Atmosphere Explosive). The vertical resistance must be below 108 Ω.
ESD
ESD Safe
ESD is an acronym for electrostatic discharge. This discharge is the rapid transfer of static between two different objects. Although ESD doesn’t typically cause harm to the human body - you might only experience it as a small, surprising shock - it can cause extensive damage to electrical equipment and sensitive instruments. This damage may either be permanent, causing the device to malfunction (known as a catastrophic failure), or it may occur on a smaller scale that would be difficult to detect before the device is sent out for service (known as latent defect).
EN 388 2016 Results: 4111AX Abrasion: 4 Cut (Coupe Test): 1 Tear: 1 Puncture: 1 Cut (TDM-100 Test): A Impact Protection: X
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
EN 388 2016 Results: 1020XX Abrasion: 1 Cut (Coupe Test): 0 Tear: 2 Puncture: 0 Cut (TDM-100 Test): X Impact Protection: X
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
ABK
EN 374 Results: ABK Type: B A: Methanol B: Acetone K: Sodium Hydroxide 40%
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
VIRUS
Protective Gloves Against Micro-organisms
The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.
Electrostatic Properties
EN 16350 European standard defines the test conditions and requirements for electrostatic properties of protective gloves used in ATEX area (Atmosphere Explosive). The vertical resistance must be below 108 Ω.
ESD
ESD Safe
ESD is an acronym for electrostatic discharge. This discharge is the rapid transfer of static between two different objects. Although ESD doesn’t typically cause harm to the human body - you might only experience it as a small, surprising shock - it can cause extensive damage to electrical equipment and sensitive instruments. This damage may either be permanent, causing the device to malfunction (known as a catastrophic failure), or it may occur on a smaller scale that would be difficult to detect before the device is sent out for service (known as latent defect).
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
VIRUS
Protective Gloves Against Micro-organisms
The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.
Electrostatic Properties
EN 16350 European standard defines the test conditions and requirements for electrostatic properties of protective gloves used in ATEX area (Atmosphere Explosive). The vertical resistance must be below 108 Ω.
ESD
ESD Safe
ESD is an acronym for electrostatic discharge. This discharge is the rapid transfer of static between two different objects. Although ESD doesn’t typically cause harm to the human body - you might only experience it as a small, surprising shock - it can cause extensive damage to electrical equipment and sensitive instruments. This damage may either be permanent, causing the device to malfunction (known as a catastrophic failure), or it may occur on a smaller scale that would be difficult to detect before the device is sent out for service (known as latent defect).
EN 388 is a European Standard. Cut Level is determined by the number of cycles it takes a spinning circular blade, that is pulled across the material under a constant weight of 500 grams, to cut the fabric. As the number of cycles increase, so does the glove's ratings. Click here for more information about the EN 388 2016 standard.
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.
VIRUS
Protective Gloves Against Micro-organisms
The EN ISO 374-5 VIRUS standard measures the ability of gloves to protect users against bacteria, fungi and viruses. Gloves with this marking must pass EN374-2 for leak testing.
Electrostatic Properties
EN 16350 European standard defines the test conditions and requirements for electrostatic properties of protective gloves used in ATEX area (Atmosphere Explosive). The vertical resistance must be below 108 Ω.
ESD
ESD Safe
ESD is an acronym for electrostatic discharge. This discharge is the rapid transfer of static between two different objects. Although ESD doesn’t typically cause harm to the human body - you might only experience it as a small, surprising shock - it can cause extensive damage to electrical equipment and sensitive instruments. This damage may either be permanent, causing the device to malfunction (known as a catastrophic failure), or it may occur on a smaller scale that would be difficult to detect before the device is sent out for service (known as latent defect).
Stock Type: Discontinued, inventory may be limited
AKL
EN 374 Results: AKL Type: B A: Methanol K: Sodium Hydroxide 40% L: Sulfuric Acid 96%
To attain the EN 374 pictogram shield gloves must pass at least a Level 2 in three chemicals. The chemicals listed above are the chemicals that passed for this glove.